COORDINATED MEP SCOPE DESK
Look inside
the coordinated MEP detail.
Mechanical, electrical and plumbing. Follow the coordinated scope through a clear, interactive view of the takeoff.
Enter the workspaceacross — workspacesQUANTITIES,
NOT PROJECT TOTALS.
01 / CHOOSE A WORKSPACE
Every component has a place.
Verified Takeoff Samples
Coordinated MEP Deliverables
Preparing verified MEP quantities… The source schedule below is available without JavaScript.
SELECTED WORKBOOK EXCERPT
Base quantities from a selected excerpt. Expand a material to inspect its saved allowance and exact source cell.
| Component / assembly | Base quantity | Unit |
|---|
No matching components.
Source categories and CSI classifications. Counts describe this selected excerpt only.
02 / PLAN CONTEXT
Connect the schedule
to the drawing.
- Source categories
- Recorded units
SOURCE SCHEDULE / AVAILABLE WITHOUT JAVASCRIPT
One coordinated excerpt, three trade schedules
These 90 selected quantities retain their original units and stored precision. They are excerpts, not complete project totals, current prices or engineering approvals. The six cropped drawings supply context, not a complete drawing set. Private pricing, client identity and original workbooks are withheld.
Division 22 — Plumbing: 19 selected lines
Review plumbing estimating scope
| Description | Base quantity | Unit | Drawing / source cell |
|---|---|---|---|
| 2" Vent Pipe | 129.29 | LF | P101,201,202 / F22 |
| 3" Vent Pipe | 60.81 | LF | P101,201,202 / F23 |
| 4" Vent Pipe | 22.3 | LF | P101,201,202 / F24 |
| 2" Sanitary Pipe | 54.4 | LF | P101,201,202 / F25 |
| 3" Sanitary Pipe | 20.89 | LF | P101,201,202 / F26 |
| 4" Sanitary Pipe | 82.79 | LF | P101,201,202 / F27 |
| 4" VTR Pipe | 1 | LF | P101,201,202 / F28 |
| 1/2" CW Pipe | 67.36 | LF | P101,201,202 / F29 |
| 3/4" CW | 83.34 | LF | P101,201,202 / F30 |
| SCO Stack Cleanout Jay R Smith #4510S(Y) | 2 | EA | P101,201,202 / F47 |
| LV1 Lavatory (ADA Accessible) Kohler #K-20000-0 "Caxton" White Viterous China | 1 | EA | P101,201,202 / F48 |
| WC-1 Water Closet (ADA Accessible) Kohler #K-3519-0 Highline Classic Floor Mounted. | 1 | EA | P101,201,202 / F49 |
| EWC Electric Water Cooler (ADA Accessible) Ellkay #LZSTL8WSLK Wall Mounted | 1 | EA | P101,201,202 / F50 |
| FCO Floor Cleanout Jay R Smith Cast Iron Body | 4 | EA | P101,201,202 / F51 |
| SK3 Sink Elkay #ELUH1116 Lustertone 14"x18 1/2" x 7 7/8" | 1 | EA | P101,201,202 / F52 |
| SK2 Sink Elkay #LR-1517-1 Lustertone 15"x17 1/2"x7 5/8" Single Compartment | 1 | EA | P101,201,202 / F53 |
| WC-2 Water Closet (ADA Accessible) Kohler #K-3519-RA-0 Floor Mounted | 1 | EA | P101,201,202 / F54 |
| LV2 Lavatory (ADA Accessible) Nameek's Cerastyle #044300U Sharp 19 3.4"x11 7/8" Wall Mounted | 1 | EA | P101,201,202 / F55 |
| Allowances For All Pipe Fittings & Insulation | 1 | LS | P101,201,202 / F74 |
Division 23 — Mechanical / HVAC: 32 selected lines
Review mechanical / hvac estimating scope
| Description | Base quantity | Unit | Drawing / source cell |
|---|---|---|---|
| 10"x12" Duct | 25.48 | LF | M101 / F80 |
| 20"x12" Duct | 17.49 | LF | M101 / F81 |
| 12" Dia Duct | 18.16 | LF | M101 / F82 |
| 10" Dia Duct | 29.82 | LF | M101 / F83 |
| 22"x14" Duct | 28.24 | LF | M101 / F84 |
| 28"x14" Duct | 12.17 | LF | M101 / F85 |
| 8" Dia Duct | 68.47 | LF | M101 / F86 |
| 10" Dia Flexible Duct | 9.48 | LF | M101 / F87 |
| PSD-1 310 CFM 4'-0" Nominal Diffuser Supply Manuf: Titus Model: PAR | 5 | EA | M101,M201 / F109 |
| LSD-1 1" Linear Slot Supply Diffuser / Return Grill Manuf: Titus Model: Flowbar FL-10-JT | 3 | EA | M101,M201 / F110 |
| CSD-1 550 CFM 24"x24" Supply Diffuser Manuf: Titus Model: Omni | 1 | EA | M101,M201 / F111 |
| CEG-1 100 CFM 24"x24" Exhaust Supply Manuf: Titus Model: Par | 2 | EA | M101,M201 / F112 |
| CRG-1 24"x24" Return Grill Manufacturer: Titus Model: Par | 12 | EA | M101,M201 / F113 |
| CSD-1 100CFM 24"x24" Supply Diffuser Manuf: Titus Model: Omni | 15 | EA | M101,M201 / F114 |
| CEG-1 75CFM 24"x24" Exhaust Supply Manuf: Titus Model: Par | 4 | EA | M101,M201 / F115 |
| CEG-2 75CFM 12"x12" Exhaust Grill Manuf: Titus Model: Par | 2 | EA | M101,M201 / F116 |
| 10"x12" To 10" Dia Duct Transition | 2 | EA | M101,M201 / F133 |
| 20"x12" To 10" Dia Duct Transition | 4 | EA | M101,M201 / F134 |
| 20"x12" To 22"x14" Duct Transition | 1 | EA | M101,M201 / F135 |
| 10"x12" To 22"x14" Duct Transition | 1 | EA | M101,M201 / F136 |
| 8" Dia To 12"x8" Duct Transition | 2 | EA | M101,M201 / F137 |
| 6" Dia To 12"x8" Duct Transition | 3 | EA | M101,M201 / F138 |
| 28"x14" To 8" Dia Duct Transition | 1 | EA | M101,M201 / F139 |
| 28" Dia To 8"x10" Duct Transition | 1 | EA | M101,M201 / F140 |
| Provide Access Panel For Duct Mounted Smoke Detector | 2 | EA | M101,M201 / F163 |
| Duct Mounted Smoke Detector | 2 | EA | M101,M201 / F164 |
| Remote Temperature | 2 | EA | M101,M201 / F165 |
| Humidity Sensor | 2 | EA | M101,M201 / F166 |
| Manual Volume Damper | 43 | EA | M101,M201 / F167 |
| Fiber Glass Duct Insulation | 2668 | SF | M101,M201 / F168 |
| Clevis Duct Hangers | 73.7 | EA | M101,M201 / F169 |
| Allowance For All Ductwork Connections | 1 | LS | M101,M201 / F170 |
Division 26 — Electrical: 39 selected lines
Review electrical estimating scope
| Description | Base quantity | Unit | Drawing / source cell |
|---|---|---|---|
| Panel Board L1 BUS AMPS: 125A Main Size/Type: MLO Volts/Phase: 208Y/120V 3P/4W AIC Rated: Fully Rated AIC Raitngs: FCA +10% Min | 1 | EA | E401 / F177 |
| Panel Board L2 BUS AMPS: 125A Main Size/Type: MLO Volts/Phase: 208Y/120V 3P/4W AIC Rated: Fully Rated AIC Raitngs: FCA +10% Min | 1 | EA | E401 / F178 |
| Panel Board MDP BUS AMPS: 400A Main Size/Type: MLO Volts/Phase: 208Y/120V 3P/4W AIC Rated: Fully Rated AIC Raitngs: FCA +10% Min | 1 | EA | E401 / F179 |
| 1P-20A Circuit Breaker | 111 | EA | E401 / F181 |
| 2P-30A Circuit Breaker | 1 | EA | E401 / F182 |
| 3P-125A Circuit Breaker | 2 | EA | E401 / F183 |
| 3P-50A Circuit Breaker | 2 | EA | E401 / F184 |
| 3P-25A Circuit Breaker | 1 | EA | E401 / F185 |
| 3P-70A Circuit Breaker | 1 | EA | E401 / F186 |
| Provide Power For Emergency Shutoff Actuator To Water Valve | 1 | EA | E101&E201 / F188 |
| 30A/3P/NF Fused Disconnect Switch | 3 | EA | E101&E201 / F189 |
| Light Control Panel Boards | 1 | EA | E101&E201 / F190 |
| Building Automation System Board | 1 | EA | E101&E201 / F191 |
| Service Access Panel | 1 | EA | E101&E201 / F192 |
| Duty Station | 3 | EA | E101&E201 / F195 |
| Occupancy Sensor Switch | 6 | EA | E101&E201 / F196 |
| Single Way Switch | 6 | EA | E101&E201 / F197 |
| 3 Way Switch | 1 | EA | E101&E201 / F198 |
| Junction Box | 22 | EA | E101&E201 / F199 |
| LV Transformer | 11 | EA | E101&E201 / F200 |
| Legrand Room Controller For Control Of Exterior Signage. Locate In Accessible Ceiling | 1 | EA | E101&E201 / F201 |
| PL Digital Room Controller For On/Off Control Of Receptacle Manuf: Acuity Nlight NPP20 PL | 2 | EA | E101&E201 / F202 |
| L38EM LED 2x2 Recessed Flat Panel LED 3000K,90CRI,3650LUM | 9 | EA | E101 / F218 |
| L38 2x2 Recessed LED Flat Panel LED 3000K,90CRI,3650LUM | 10 | EA | E101 / F219 |
| L39 2'x2' Recessed LED Flat Panel LED4000K 90CRI 3700 LUM | 2 | EA | E101 / F220 |
| L39EM 2'x2' Recessed LED Flat Panel LED 4000K 90CRI 3700LUM | 2 | EA | E101 / F221 |
| L19 LED 2'x2' Edgelit Aluminum Frame LED 3000K, 80CRI 3100LUM | 6 | EA | E101 / F222 |
| L41 2x4 Recessed LED Flat Panel LED 3000K 90CRI 5200LUM | 6 | EA | E101 / F223 |
| L06 Linear LED Tape Light In Recessed Channel 3000k 90CRI,235LUM/LF | 9 | EA | E101 / F224 |
| L19EM LED 2'x2' Edgelit Aluminum Frame 3000K 80CRI 3100LUM | 2 | EA | E101 / F225 |
| Provide Single Gang Box W/USB-C & Data Sleeve Above Ceiling W 10 Feet/100W Charging Cable Routed Door Jamb To Glass Mounted Tablet | 4 | EA | E202 / F251 |
| (Wireless Access Point) Provide Single Gang Box W/USB-C & Data Sleeve Above Ceiling W 10 Feet/100W Charging Cable Routed Door Jamb To Glass Mounted Tablet | 4 | EA | E202 / F252 |
| Mini Split Camera Provide Single Gang Box W/USB-C & Data Sleeve Above Ceiling W 10 Feet/100W Charging Cable Routed Door Jamb To Glass Mounted Tablet | 4 | EA | E202 / F253 |
| Siren & Strobe Provide Single Gang Box W/USB-C & Data Sleeve Above Ceiling W 10 Feet/100W Charging Cable Routed Door Jamb To Glass Mounted Tablet | 3 | EA | E202 / F254 |
| Camera Provide Single Gang Box W/USB-C & Data Sleeve Above Ceiling W 10 Feet/100W Charging Cable Routed Door Jamb To Glass Mounted Tablet | 10 | EA | E202 / F255 |
| Motion Sensor Provide Single Gang Box W/USB-C & Data Sleeve Above Ceiling W 10 Feet/100W Charging Cable Routed Door Jamb To Glass Mounted Tablet | 2 | EA | E202 / F256 |
| Panic Button | 1 | EA | E202 / F257 |
| Door Contact | 4 | EA | E202 / F258 |
| Allowance For All Conduits,Wiring & Dataport Cables | 1 | LS | E101,201,202,401 / F267 |
For coordinated review, confirm equipment electrical connections, condensate and water connections, controls, supports and penetrations with the responsible trades. This excerpt does not demonstrate a clash-free BIM model or specialty process-system capability.
FROM SCOPE TO YOUR NEXT BID
Your plans.
Coordinated MEP quantities you can review.
Share your drawing set, scope notes, and bid deadline to confirm deliverables and pricing.